2009年3月30日 星期一

Gas Valve (Single stage Manual Valve)

CSA:

http://directories.csa-international.org/cert_rec_srch.asp?txtDir=*&Submit=Search&txtCustomer=seven+universe&txtProvState=&txtCountry=Taiwan&txtFile=&txtMajorClass=&txtMinorClass=&txtClassDesc=&txtKeyword=






CB00B
Aluminum valve: CB type 0 degree
Life test: 40,000cycle between 120℃ and 20℃ Ambient temperature:
Leaking <15CC/hr, Working toque<0.4N-M




CB90B

Aluminum valve: CB type 90 degree


Life test: 40,000cycle between 120℃ and 20℃ Ambient temperature: Leaking <15cc/hr,>





CA103B


Aluminum Safety valve: CA type 103 degree


Life test: 40,000cycle between 120℃ and 20℃ Ambient temperature: Leaking <15cc/hr,>

CSA,CE approval

Regulator (Low Inlet pressure types 1/2psi Max.)


GR250 GR120 GR60 Outlet pressure: N: for Natural Gas(3”W.C.~5”W.C.) P: for LPG(8”W.C.~10”W.C.) C: 10”W.C. for LPG; 4”W.C. for N.G. Connect size GR60: Inlet(3/8NPT),Outlet(3/8NPT) GR120:Inlet(3/8,1/2NPT),outlet(3/8,1/2NPT) GR250:Inlet(1/2,3/4NPT),Outlet(1/2,3/4NPT) Application:For main/pilot burner load-delta-P Temperature range-Ambient:32°F~225°F(Special type 0°F~300°F) Inlet pressure rate: 1/2psi CapacitiesIndividual load-Maximum: GR60: 60,000Btu/hr GR120:120,000Btu/hr GR250:250,000Btu/hr *Base on a gas having a heating value of 1,000Btu per cubic foot and a specific gravity of 0.64 at pressure drop of 1.0”W.C. CSA approval

Function upgrade for(GR(60,120,250) type: improved the flow rate function.
New 2018, GR(60,120,250)(N,P,C)-2P: 2psi inlet pressure with Vent Limiter.
New 2022, GR30(N,P,C)

2009年3月13日 星期五

Regulator(High Inlet pressure types)












GCC(QCC)+GR100+Hose





GR100:
Flow rate:100,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
Inlet pressure: from 25psig to 250psig
Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
Outlet connection:Hose or fitting









GR100 GR55
QCC+Regulator+Hose




GR55:
Flow rate:55,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
Inlet pressure: from 25psig to 250psig
Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
Outlet connection:Hose or fitting




QCC+GR150+Hose



GR150:
*Flow rate:150,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
*Outlet connection:Hose or fitting







G2R150: Two stage Regulator
*Flow rate:150,000Btu/Hr Max. at 11"W.C. outlet pressure(Second stage), LPG.
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
*Outlet connection:Hose or fitting









GR25AGR25B



GR25(A,B)
*Flow rate:25,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
*Inlet pressure: from 25psig to 250psig
*Inlet connection:1Lb Cylinder
*Recommend Flow rate:12,000Btu/hr Max. with 1Lb Cylinder
*Outlet pressure:11"W.C.



GR25D
*Flow rate:25,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG
*Inlet pressure: from 25psig to 250psig
*Inlet connection:1Lb Cylinder
*Recommend Flow rate:12,000Btu/hr Max. with 1Lb Cylinder
*Outlet pressure:From Off and Low(5"W.C.) to High(18.5"W.C.)





GR80(High pressure outlet)
*Flow rate:80,000Btu/Hr Max. at 5psi(10psi or 15psi)outlet pressure, LPG
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type or fitting or connection
*Outlet connection:High pressure Hose or fitting
*Outlet pressure:From Off and Low to high(5psi,10psi or 15psi request from customer)



*All type can connect with our Valve to the outlet.

CSA approval

Gas control valve(BZ Type)












Type #:BZA01A0201
Inlet-Outlet:3/8NPT-3/8NPT
Outlet pressure:10.5"W.C. for LPG
12VDC at 0.48A
64700Btu/hr,1.0"W.C.pressure drop with LPG.
Max.pressure: 1/2psig
CSA approval


All types we have CSA approval:
BZ(A,B,C,D,E,F,G)02(A,B,C,D,E)(01,02,03,04,05,06,07,08,10,11)
Temperature range-Ambient:
Max. 200°F(93.3°C)
min. -40°F(-40°C)
Flow Rate:
LPG:64700Btu/hr,1"W.C.pressure drop
N.G.:40000Btu/hr,1"W.C.pressure drop

Outlet Orientation:
A = Straight Thru Outlet
B = 90 Degree Left Outlet
C = 90 Degree Right Outlet
D = Dual Outlet (L+R)
E = Dual Outlet (L+Str)
F = Dual Outlet (R+Str)
G = Left Inlet 90 Degree Outlet

Inlet/Outlet Specification:
01 = 3/8NPT, 3/8NPT
02 = 1/4NPT, 1/4NPT
03 = 1/4NPT, 3/8NPT
04 = 3/8NPT, 1/4NPT
05 = 13/16-18NS (inlet), orifice (outlet)

Automatic Valve Voltage:
A = 12 volt DC
B = 24 volt AC (50/60 Hz)
C = 12 volt DC with wire
D = 24 volt AC (50/60 Hz) with wire
E = 120 volt AC (50/60 Hz)

Outlet Pressure Regulator Setting:
01 = 10 Inch Water Column
02 = 10.5 Inch Water Column
03 = 3.5, 10.5 Inch Water Column, convertible
04 = 10/5.5 Inch Water Column, Hi-Lo solenoid employed
05 = 10/4.9 Inch Water Column, Hi-Lo solenoid employed
06 = 3.0 Inch Water Column
07 = 3.5 Inch Water Column
08 = 4.0 Inch Water Column
10 = 11 Inch Water Column
11 = Non-regulated

Outlet Pressure:
No. (BZ)XXXX01 - 10 inch water column
No. (BZ)XXXX02 - 10.5 inch water column
No. (BZ)XXXX03 - 3.5/10.5 inch water column - convertible
No. (BZ)XXXX04 - 10/5.5 inch water column – Hi/Lo solenoid
No. (BZ)XXXX05 - 10/4.9 inch water column – Hi/Lo solenoid
No. (BZ)XXXX06 - 3.0 inch water column
No. (BZ)XXXX07 - 3.5 inch water column
No. (BZ)XXXX08 - 4.0 inch water column
No. (BZ)XXXX10 - 11 inch water column
No. (BZ)XXXX11 - Non-regulated

Type#.BZA01B0301
Inlet-Outlet:3/8NPT-3/8NPT
Outlet pressure:LPG 10.5"W.C./NG 3.5"W.C.
24VAC at 0.35A
64,700Btu/hr,1"W.C.pressure drop for LPG.
40,000Btu/hr,1"W.C.pressure drop for N.G.
Max.pressure:1/2psig
CSA approval

Type#.BZA01C0101
Inlet-Outlet:3/8NPT-3/8NPT
Outlet pressure:10"W.C.
12VDC at 0.48A
64,700Btu/hr,1"W.C.pressure drop for LPG
Max. pressure:1/2psig
CSA approval


Type#.BZB01A0201
Inlet-Outlet:3/8NPT L 3/8NPT
Outlet pressure:10.5"W.C.
12VDC at 0.48A
64,700Btu/hr,1"W.C.pressure drop for LPG.
Max.pressure 1/2 psig
CSA approval

Type#.BZB01A0401
Inlet-Outlet:3/8NPT L 3/8NPT
Outlet pressure:High 10"W.C. & Low 5.5"W.C.
12VDC at 0.48A(0.73A)
64,700Btu/Hr,1"W.C.pressure drop for LPG.
Max. pressure:1/2psig
CSA approval

Type#.BZB01A0501
Inlet-Outlet:3/8NPT L 3/8NPT
Outlet pressure:High 10"W.C. & Low 4.9"W.C.
12VDC at 0.48A(0.73A)
64,700Btu/hr,1"W.C.pressure drop for LPG.
Max.Pressure:1/2psig
CSA approval

Type#.BZB01B0301
Inlet-Outlet:3/8NPT L 3/8NPT
Outlet Pressure:10.5"W.C. LPG; 3.5"W.C.N.G.
24VDC at 0.35A
64,700Btu/hr,1"W.C.pressure drop for LPG.
40,000Btu/hr,1"W.C.pressure drop for N.G.
Max pressure:1/2psig
CSA approval

2009年3月2日 星期一