2010年8月17日 星期二
2009年10月15日 星期四
2009年7月27日 星期一
Burner set(2009/7/27)
2009年3月30日 星期一
Gas Valve (Single stage Manual Valve)
Aluminum valve: CB type 0 degree
Life test: 40,000cycle between 120℃ and 20℃ Ambient temperature:
Leaking <15CC/hr, Working toque<0.4N-M
Regulator (Low Inlet pressure types 1/2psi Max.)


2009年3月13日 星期五
Regulator(High Inlet pressure types)
Flow rate:100,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
Inlet pressure: from 25psig to 250psig
Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
Outlet connection:Hose or fitting

GR100 GR55
QCC+Regulator+Hose
GR55:
Flow rate:55,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
Inlet pressure: from 25psig to 250psig
Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
Outlet connection:Hose or fitting
QCC+GR150+Hose
GR150:
*Flow rate:150,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
*Outlet connection:Hose or fitting

*Flow rate:150,000Btu/Hr Max. at 11"W.C. outlet pressure(Second stage), LPG.
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type of fitting or connection
*Outlet connection:Hose or fitting
GR25AGR25B
GR25(A,B)
*Flow rate:25,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG.
*Inlet pressure: from 25psig to 250psig
*Inlet connection:1Lb Cylinder
*Recommend Flow rate:12,000Btu/hr Max. with 1Lb Cylinder
*Outlet pressure:11"W.C.
GR25D
*Flow rate:25,000Btu/Hr Max. at 11"W.C. outlet pressure, LPG
*Inlet pressure: from 25psig to 250psig
*Inlet connection:1Lb Cylinder
*Recommend Flow rate:12,000Btu/hr Max. with 1Lb Cylinder
*Outlet pressure:From Off and Low(5"W.C.) to High(18.5"W.C.)
GR80(High pressure outlet)
*Flow rate:80,000Btu/Hr Max. at 5psi(10psi or 15psi)outlet pressure, LPG
*Inlet pressure: from 25psig to 250psig
*Safety:Lock out when over flow and over temperature.(connect to GCC or QCC)
*Inlet connection:POL,GCC(QCC) or other thread type or fitting or connection
*Outlet connection:High pressure Hose or fitting
*Outlet pressure:From Off and Low to high(5psi,10psi or 15psi request from customer)
*All type can connect with our Valve to the outlet.
CSA approval
Gas control valve(BZ Type)

Type #:BZA01A0201
Inlet-Outlet:3/8NPT-3/8NPT
A = Straight Thru Outlet
B = 90 Degree Left Outlet
C = 90 Degree Right Outlet
D = Dual Outlet (L+R)
E = Dual Outlet (L+Str)
F = Dual Outlet (R+Str)
G = Left Inlet 90 Degree Outlet
01 = 3/8NPT, 3/8NPT
02 = 1/4NPT, 1/4NPT
03 = 1/4NPT, 3/8NPT
04 = 3/8NPT, 1/4NPT
05 = 13/16-18NS (inlet), orifice (outlet)
A = 12 volt DC
B = 24 volt AC (50/60 Hz)
C = 12 volt DC with wire
D = 24 volt AC (50/60 Hz) with wire
E = 120 volt AC (50/60 Hz)
Outlet Pressure Regulator Setting:
01 = 10 Inch Water Column
02 = 10.5 Inch Water Column
03 = 3.5, 10.5 Inch Water Column, convertible
04 = 10/5.5 Inch Water Column, Hi-Lo solenoid employed
05 = 10/4.9 Inch Water Column, Hi-Lo solenoid employed
06 = 3.0 Inch Water Column
07 = 3.5 Inch Water Column
08 = 4.0 Inch Water Column
10 = 11 Inch Water Column
11 = Non-regulated
No. (BZ)XXXX01 - 10 inch water column
No. (BZ)XXXX02 - 10.5 inch water column
No. (BZ)XXXX03 - 3.5/10.5 inch water column - convertible
No. (BZ)XXXX04 - 10/5.5 inch water column – Hi/Lo solenoid
No. (BZ)XXXX05 - 10/4.9 inch water column – Hi/Lo solenoid
No. (BZ)XXXX06 - 3.0 inch water column
No. (BZ)XXXX07 - 3.5 inch water column
No. (BZ)XXXX08 - 4.0 inch water column
No. (BZ)XXXX10 - 11 inch water column
No. (BZ)XXXX11 - Non-regulated